Filter Cover- P/N 159-T-61, Pkg. of 6
N95 Filter Pad- P/N 158-D-N5, Box of 16
N99 Filter Pad- P/N 158-D-N9, Box of 16
Filter Holder- P/N 14880, Pkg. of 6
|
N95
- Approved for minimum 95% efficient protection against non-oil
particulates.
N99 - Approved for
minimum 99% efficient protection against non-oil particulates.
Typical applications:
For welding on steel or aluminum, use an N95 pad and a Half-Mask
respirator.
If concentrations are higher, use an N99 pad and a Full Face respirator
with welding adapter.
Also used for woodworking or general dust environments, protection against
sodium salts,
aluminum oxides & silicates, carbon black, paper dusts, cotton dusts,
fiberglass, gypsum,
graphite and mineral or rock
dusts.
CDC recommended for protection against Tuberculosis. |
 |
| Organic Vapor- P/N 158-T-20, Box of 6 |
For
protection against organic vapors.
Typical applications include protection against lacquer thinners,
petroleum distillates, naptha, acetone, isopropyl alcohol, toluene &
stoddard solvent. |
|
Acid Gas- P/N 158-T-21, Box of 6 |
For protection
against chlorine, hydrogen chloride, sulfur dioxide and chlorine
dioxide.
Typical applications include cleaning or etching (e.g. metal or concrete)
with the acids listed. Also used for protection against muratic acid. |
|
Ammonia & Methyl Amine- P/N 158-T-22, Box of 6 |
For protection
against ammonia or methyl amine. |
|
Acid Gas & Organic Vapor- P/N 158-T-26, Box of 6 |
For protection
against organic vapors, chlorine, hydrogen chloride, sulfur dioxide and
chlorine dioxide.
Typical applications include anywhere there is a combination of acid gases
and organic vapors. Some cleaning compounds contain both. |
|
Formaldehyde- P/N 158-T-29, Box of 6 |
For
protection against formaldehyde. Eye protection is required (goggles or
full face respirator). |
 |
Retainer-P/N 14881, Pkg. of 6
N95 Filter Pad- P/N 158-D-N5, Box of 16
N99 Filter Pad- P/N 158-D-N9, Box of 16
Gas/Vapor Cartridge (see above for P/N) |
Select a filter pad, then select either the retainer or the optional cover
to easily add particulate protection to any gas/vapor cartridge.
In general, select an N95 pad for lower
concentrations where a Half-Mask respirator will be used and
select an N99 pad for higher concentrations where a Full Face respirator
will be used.
The retainer is an open top design that works in any
application, but is specially designed to to be used in heavy dust/mist
applications without clogging.
Typical applications:
Protecting against misting or splashing of the liquid of the gas/vapor
contaminants listed above.
Also used where there is a combination of any of the particulate hazards
listed in the first row and also any of the gas/vapors listed above. |
 |
OV/N95 with
Retainer, 158-T-20DN5, Box of 2
|
Approved for organic vapors and
minimum 95% efficient protection against non-oil particulates.
This combination is best suited for
lacquer & enamel paints (including applying oil-based paints) and also
most commercially available pesticides. Also used for some concrete and
floor sealers.
Advantages: Unique
filter design has low breathing resistance and resists clogging so you don’t
need a special pre-filter.
Note: Not for use
against paints containing isocyanates. If the pesticide contains oil, use
the Diskit-R95 shown below. |
 |
N99- P/N DiskitN99, Box of 12 pair
N100- P/N P/N DiskitN100, Box of 12 pair
R95- P/N DiskitR95, Box of 12 pair
R100- P/N DiskitR100, Box of 12 pair
P100- P/N DiskitP100, Box of 12 pair |
N99-Approved
for minimum 99% efficient protection against non-oil particulates.
Typical
applications: welding, woodworking & dusts, fumes or mists. Also
used for protection against Tuberculosis, and, if combined with an
organic vapor cartridge, paint spray & pesticides.
N100-Approved for minimum 99.97%
efficient protection against non-oil particulates.
Typical applications:
battery plants, nuclear power facilities, asbestos abatement (specific
limitations apply see OSHA 1910.1001) and remediation, lead, cadmium,
silver,
cobalt fume & dust, radionuclides and radon
daughters. Also
used for dusts, fumes, & mists with a PEL less than 0.5mg per cubic
meter.
R95-Approved
for minimum 95% efficient protection against oil & non-oil
particulates.
Typical applications:
metal working with oil mists, such as grinding or machining with oil
lubricants. Also used for protection against glycerin mists, welding,
woodworking, and,
if combined with an organic vapor cartridge,
paint spray & pesticides.
R100-Approved
for minimum 99.97% efficient protection against oil & non-oil
particulates.
Typical applications:
lead, welding, metal working with oil mists, such as grinding or machining
with oil lubricants, and radionuclides and radon daughters.
P100-Passes
NIOSH’s most rigorous testing criteria and is approved for minimum
99.97% efficient protection against oil & non-oil particulates.
Typical applications:
battery plants, nuclear power facilities, asbestos abatement (specific
limitations apply see OSHA 1910.1001) and remediation, lead, cadmium,
silver,
cobalt fume & dust, radionuclides and radon
daughters.
Also used for dusts, fumes, & mists with a PEL
less than 0.5mg per cubic meter. |
 |
Diskit, (see above for P/N)
Adapter- P/N 14890, Box of 10 pair
Gas/Vapor Cartridge (see above for P/N)
|
Select the appropriate gas/vapor
cartridge for your application and then select the Diskit filter that
meets your particulate protection needs.
The durable, reusable adapter allows you to easily replace the cartridge
or filter when they expire.
Typical applications:
An R95/Organic Vapor can be used around plastics processing where there
are vapors & glycerin mists. It can also be used for pesticides
containing oil & for paint spray operations.
An N99/Organic Vapor is suitable for lacquer and enamel paints &
non-oil pesticides.
An R100/Organic Vapor/Acid Gas can be used where there is repair welding
on machinery coated with oil, dirt, and grime. |
 |
Retainer for Pre-Filter- P/N 14879, Pkg. of 6
Optional Pre-Filter for P100- P/N 14494, Box of 24
Low Profile P100 Filter- P/N 158-T-LP0, Box of 6 |
P-100 - Approved for minimum
99.97% efficient protection against oil & non-oil particulates.
This low-profile filter passes NIOSH’s most rigorous particulate test
criteria. It is packaged in a sturdy molded housing, so there is no chance
of filter damage.
The low-profile P100 has been engineered to provide low breathing
resistance & long life, at an economical price.
The optional pre-filter is best used in heavy dust applications. It will
extend the life of the P100 filter because it prevents larger particles
from rapidly clogging the high efficiency media.
Typical applications:
Any application which required a 30CFR11 HEPA filter such as lead,
cadmium, asbestos (specific limitations apply, see OSHA 1910.1001),
radionuclides and radon daughters. |
 |
Retainer for Pre-Filter- P/N 14879, Pkg. of 6
Optional Pre-Filter for P100- P/N 14494, Box of 24
Low Profile P100 Filter- P/N 158-T-LP0, Box of 6
|
The sturdy, low profile P100 shown
above is available permanently sealed to any U.S. Safety cartridge. This
provides the ultimate protection & durability at a very affordable
price.
The optional pre-filter is best used in heavy dust applications. It will
extend the life of the P100 filter because it prevents larger particles
from rapidly clogging the high efficiency media.
Typical applications:
The Acid Gas/Organic Vapor/P100 is commonly used in metal smelting or
forging, such as steel mills or mining and post mining operations.
These filters are also used anywhere there is a combination of particulate
& gas/vapor contaminants where the particulate hazard requires a P100
filter. |
|
* DO NOT
use N Series products for protection against oil aerosols, such as
grinding with oil-based lubricants or processes with glycerin mists.
** When R Series products are exposed to oil, a one shift (8 hour) time
use limit applies.
WARNINGS:
1. Selection & typical applications shown are a
guideline only.
Prior to selecting a respirator, the workplace hazards
must be evaluated by a qualified Industrial Hygienist, who will
determine
the appropriate cartridge, filter, and facepiece
as well as use limitations.
2. Respirators must be selected, fitted, used and maintained in accordance
with MSHA, OSHA
and other applicable regulations as well as ANSI Z88.2.
3. Do not exceed maximum use concentrations as established by regulatory
guidelines.
4. Never use a half-mask respirator where contaminant concentrations
exceed 10 times the PEL or TLV.
5. Never use a full facepiece respirator where contaminant concentrations
exceed 50 times the PEL or TLV.
6. Before using any respirator, READ and UNDERSTAND the instructions
provided with the respirator facepiece
assembly as well as the Cautions and Limitations listed
on the enclosed NIOSH approval matrix.
7. Although this respirator reduces exposure to certain contaminants,
it
DOES NOT completely eliminate your exposure or risk.
Misuse of this product or failure to follow the warnings
may result in sickness or even death. For proper
use,
consult a qualified safety professional or call U.S.
Safety at 1-800-821-5218. |